positive airway pressure machine

Positive airway pressure (PAP) is a mode of respiratory ventilation used primarily in the treatment of sleep apnea, for which it was first developed. PAP ventilation is also commonly used for those who are critically ill in hospital with respiratory failure, and in newborn infants (neonates). In these patients, PAP ventilation can prevent the need for tracheal intubation, or allow earlier extubation. Sometimes patients with neuromuscular diseases use this variety of ventilation as well. CPAP is an acronym for "continuous positive airway pressure", which was developed by Dr. George Gregory and colleagues in the neonatal intensive care unit at the University of California, San Francisco.[1] A variation of the PAP system was developed by Professor Colin Sullivan at Royal Prince Alfred Hospital in Sydney, Australia, in 1981.
CPAP system NLF-200A Usage:
CPAP system is used for newborn baby with stronger spontaneous breath and slightly respiratory failure ,and applies to pediatric clinics for NCPAP oxygen uptake
Technical specification of NLF-200A CPAP system
•Oxygen concentration : 21%~100%
•CPAP adjusting range:0cmH2O~15cmH2O
•Continuous flow range: 2L/min~20L/min
•Alarm
CPAP system NLF-200A Features :
1.CPAP ventilation mode keeps children spontaneous breath and ;
2.Provide CPAP mode of constant flow and limited pressure for newborn baby;
3.Offer manual ventilation mode of pressure limit, doctors can operate by the buttons replacing manual bag ventilation to save treatment time;
4.Delivery air/ O2 mixture with properly adjusted O2 concentration and continuous positive pressure to premature baby, newborn baby and child, which will highly improve the safety and efficacy of oxygen therapy;
5.Equipped with built-in oxygen/air blender ,ensuring O2 concentration adjustment to be stable;
6.High quality oxygen sensor can monitor real-time O2 concentration , alarm over limitation, ensure safety of breathing O2;
7.Offer manual ventilation mode of pressure limit, doctors can operate by the buttons replacing manual bag ventilation to save treatment time.
8.Reliable CPAP control valve and advanced pressure monitoring system improve CPAP adjustment precision;
9.Optional parts: air compressor, humidifier with heating device;
10.Equipped with built-in backup battery, when AC power failure, backup power can work for 2 hours;
11.TFT sreen;