cpap machine

, according to the connection with the patient can be divided into:
Noninvasive ventilator: breathing machine, through the mask to connect with the patient
Have a breathing machine, breathing machine through endotracheal intubation is connected to the patients
2, according to use classification (six) : emergency breathing machine: dedicated to the scene first aid. Breath therapy ventilation machine: for a long time in patients with respiratory insufficiency ventilatory support and respiratory therapy. Anesthesia ventilator: dedicated to anesthesia breathing management. Pediatric respiratory machine: special without and newborn ventilatory support and respiratory therapy. High frequency respirator: have ventilatory frequency > 60 times/min. Noninvasive ventilator: through the mask or nasal mask ventilation support.
3, according to the driving mode classification (three) :
Pneumatic pneumatic ventilator, air supply and control system are only powered by oxygen source. Portable emergency breathing machine. Electric control breathing machine, air supply and control system are powered by power supply, internal cylinder, piston pump, etc., function is relatively simple breathing machine.


CPAP system NLF-200A Usage:
CPAP system is used for newborn baby with stronger spontaneous breath and slightly respiratory failure ,and applies to pediatric clinics for NCPAP oxygen uptake
Technical specification of NLF-200A CPAP system
•Oxygen concentration : 21%~100%
•CPAP adjusting range:0cmH2O~15cmH2O
•Continuous flow range: 2L/min~20L/min
•Alarm


CPAP system NLF-200A Features :
1.CPAP ventilation mode keeps children spontaneous breath and ;
2.Provide CPAP mode of constant flow and limited pressure for newborn baby;
3.Offer manual ventilation mode of pressure limit, doctors can operate by the buttons replacing manual bag ventilation to save treatment time;
4.Delivery air/ O2 mixture with properly adjusted O2 concentration and continuous positive pressure to premature baby, newborn baby and child, which will highly improve the safety and efficacy of oxygen therapy;
5.Equipped with built-in oxygen/air blender ,ensuring O2 concentration adjustment to be stable;
6.High quality oxygen sensor can monitor real-time O2 concentration , alarm over limitation, ensure safety of breathing O2;
7.Offer manual ventilation mode of pressure limit, doctors can operate by the buttons replacing manual bag ventilation to save treatment time.
8.Reliable CPAP control valve and advanced pressure monitoring system improve CPAP adjustment precision;
9.Optional parts: air compressor, humidifier with heating device;
10.Equipped with built-in backup battery, when AC power failure, backup power can work for 2 hours;
11.TFT sreen;