How to maintain respiratory ventilation machines?

 Familiar with the ventilator tube, proper drainage of condensate in a timely manner a disposable condensation of water, the operation should prevent the drainage was poured influenza respiratory. The medical staff should wash their hands before and after handling the ventilator, to prevent cross-infection occurs.
Make a record a variety of maintenance, replacement, calibration records to the record in detail, such as record maintenance parts, error or the extent of the damage, the time, replacement parts name, time, number, etc., in order to check.
General ventilator oxygen source should ensure that oxygen decompression pressure 0.35-0.4Mpa with compression pump output pressure balance, the pressure of the oxygen in the table under 5 should be replaced with oxygen, the oxygen switch should start slowly, to avoid damage to the pressure gauge.

The host power gas source is turned on before the start, which is to start the air compressor pump power and turn on the oxygen balance to be oxygen and air pressure, in order to turn on the console, the alarm sound for sound leakage or gas source disappears. Ventilator shutdown sequence happened to the contrary, that is, first power off the host, and then turn off the gas source.
A heated humidifier is part of the regular replacement and supplement the liquid inside the humidifier, note that the liquid can only use distilled water, pay attention to check the thermostat performance, protection thermostat sensor, close observation of the temperature alarm condition of
medical ventilator.  
If you have any questions, please feel free to contact us.

评论

此博客中的热门博文

630mA Radiography X ray Machin | price of DR system PLD6000

microplate reader 9602

Medical Mammography X Ray System (BTX-9800 series)