What kind of problems when using the monitor is easy to be ignored

Monitor (ecg monitoring instrument, multi-parameter monitor) is commonly used in the hospital basic equipment, but also an important medical equipment allocation of hospital, is a kind of science and technology products, usually used in hospital are professional after training, the staff in the operation, but even if is in use process middling professional operators often ignore some details. The perlong medical treatment for everyone to introduce monitor what problem in use process is easy to be ignored. There are three points worth particular attention:

First, blood pressure monitor is easy to ignore the problem
1, sleeve with quantity to prepare enough, do the specialist special. Even monitor instrument to inadequate preparation, bed bed between Shared a monitor, sleeve with fixed application, also need to change the sleeve when measuring with joint part. In this way can effectively avoid cross infection, and also can prevent the psychological is caused to the patients and their relatives.
2, for the continuous monitoring of the patient, must do after the 1 to 2 times to relax. If condition permits, suggested that apart from six to eight hours should be replaced monitoring site once. In order to avoid same part for continuous monitoring of the patient, the patient cause skin damage.
3, continuous monitoring blood pressure monitor is used for more than 3 days of patients, medical staff should pay attention to sleeve belt should change in time, clean and disinfect.
4, sleeve with nylon buckle lax, fuarding personnel shall timely change, take. To prevent the error increase.
5, for adults, children's measure blood pressure, must pay attention to the cuffs, selection of pressure value adjustment, avoid confusion.
6, the patient in the case of the restless measured value is very don't have frequency measuring error. For severe shock, heart rate less than every 40 times; More than 200 times per minute; Measured results should be compared with artificial measurement results, combined with the clinical observation.

Second, blood oxygen saturation, heart rate measurement is easy to ignore the problem
1, monitor instrument precision, guardian should pay attention to take good care of the probe, Use tape fixed; To avoid accidentally collision, loss, damage, etc.; Cause unnecessary waste.
2, electrode used for a long time is easy to fall off, this will affect the accurate value and monitoring quality. 3 to 4 days should change at a time; At the same time pay attention to the cleaning and disinfection of the skin.
Third, do a good job the relatives of the patients with extremely explain
1, most of the patients with extremely relative to monitor will have a lot of curiosity. Monitor the little changes can cause the patient or family, wonder, panic. So before using monitor monitoring in patients with the best and full, the necessary related explanation. Avoid a dispute, in order of nursing work.
2, they also need to charge with extremely relatives shall not without authorization application, adjust the monitor, lest cause the damage of the instrument.

After watching the content of the above, do you think a lot? Believe after above to monitor when use easy to ignore the problem, after the introduction of you to monitor in the care of the patients at the time of the relevant information has been understanding, if you feel still don't understand, you can call perlong medical free telephone consultation, and can also more information of medical equipment, features, price, etc. Welcome your consultation.



(perlong medical brand - JP2000-09 thin multi-parameter monitor)



 