The enzyme-linked immune detector, is a special instrument enzyme-linked immunosorbent assay. Can be simply divided into semi-automatic and fully automatic 2 broad categories, but its working principle are basically consistent, its core is a colorimeter, use colorimetric method to analyze the content of antigen or antibody. ELISA reader was developed for the determination of general requirements test fluid eventually under 250 u l size, using photoelectric colorimeter was unable to complete the test, so the photoelectric colorimeter in enzyme standard instrument have special requirements.
A, technical parameters
1, the measurement system: 8 light detection
* 2, the wavelength range: 400 nm to 800 nm, resolution: 0.001 ABS
* 3. The measuring range: 0.000 to 4.000 Abs;
4, right: + 1.0% or + / - 0.01 (when measuring range between 0.1 to 1.5)
5, repeatability: 0.5% or less
6, stability: A 0.005 mm or less
7, linear error: plus or minus 1.0% (when measuring range between 0.1 to 1.5)
* 8, sparkling pieces: standard for 405, 450, 492 and 450 nm, loadable 10 filter, the rest of the wavelength is optional.
9, instrument with a single, dual wavelength detection two functions for users to choose;
10, instrument with functions of absorbance, qualitative and quantitative analysis;
11, instrument can output 10 kinds of data, absorbance values, the critical value, the result of masculine, semi-quantitative value and the concentration of the normal reference value, judgment, results, data quality control, quality control charts, the calibration curve; Can arbitrarily six project storage, query, and print the full month of data quality control and quality control curve; Through the touch screen can input lowercase letters and three Chinese characters input method for users to choose; You can print 1000 patients comprehensive report.
1, the measurement system: 8 light detection
* 2, the wavelength range: 400 nm to 800 nm, resolution: 0.001 ABS
* 3. The measuring range: 0.000 to 4.000 Abs;
4, right: + 1.0% or + / - 0.01 (when measuring range between 0.1 to 1.5)
5, repeatability: 0.5% or less
6, stability: A 0.005 mm or less
7, linear error: plus or minus 1.0% (when measuring range between 0.1 to 1.5)
* 8, sparkling pieces: standard for 405, 450, 492 and 450 nm, loadable 10 filter, the rest of the wavelength is optional.
9, instrument with a single, dual wavelength detection two functions for users to choose;
10, instrument with functions of absorbance, qualitative and quantitative analysis;
11, instrument can output 10 kinds of data, absorbance values, the critical value, the result of masculine, semi-quantitative value and the concentration of the normal reference value, judgment, results, data quality control, quality control charts, the calibration curve; Can arbitrarily six project storage, query, and print the full month of data quality control and quality control curve; Through the touch screen can input lowercase letters and three Chinese characters input method for users to choose; You can print 1000 patients comprehensive report.